Ditch-witch RT45 Uživatelský manuál Strana 16

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 203
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 15
RT45 Operators Manual Safety - 17
Emergency Procedures
CMW
®
If a Gas Line is Damaged
If you suspect a gas line has been damaged, take the following actions. The order and degree of action will
depend on the situation.
Immediately shut off engine(s), if this can be done safely and quickly.
Remove any ignition source(s), if this can be done safely and quickly.
Warn others that a gas line has been cut and that they should leave the area.
Leave jobsite as quickly as possible.
Immediately call your local emergency phone number and utility company.
If jobsite is along street, stop traffic from driving near jobsite.
Do not return to jobsite until given permission by emergency personnel and utility company.
Fire or explosion possible. Fumes could ignite and cause
burns. No smoking, no flame, no spark. 275-419 (2P)
Explosion possible. Serious injury or equipment damage could occur.
Follow directions carefully.